Products · Pumps产品 · 水泵

Which pumps run at variable speed, how large, and with which drives?哪些泵能变频、做到多大、配什么变频器?

All three makers offer variable speed in two forms.三家都提供两种变频方式。

Drives built into the pump are stated up to 22–⁠55 kW (Armstrong to 450 hp); larger plant pumps use separate drives.一体式驱动写明到 22–⁠55 kW(Armstrong 到 450 hp);更大的冷站水泵配独立变频器。

Evidence checked 2026-10-17证据核查 2026-10-17

How large each line goes: drive on the pump, pump without a built-in drive, or separate drive各系列做到多大:驱动装在泵上、泵上不带变频器的泵或独立变频器
Grundfos · NBE / NKEGrundfos · NBE / NKE 55 kW · drive on the pump55 kW · 驱动装在泵上Armstrong · Design Envelope TangoArmstrong · Design Envelope Tango 37 kW · drive on the pump37 kW · 驱动装在泵上Grundfos · TPE3 / TPE3 DGrundfos · TPE3 / TPE3 D 22 kW · drive on the pump22 kW · 驱动装在泵上Wilo · Stratos GIGA2.0-I / -DWilo · Stratos GIGA2.0-I / -D 22 kW · drive on the pump22 kW · 驱动装在泵上Grundfos · NBSEGrundfos · NBSE 15 hp · drive on the pump15 hp · 驱动装在泵上Wilo · Stratos GIGA2.0-BWilo · Stratos GIGA2.0-B 7.5 kW · drive on the pump7.5 kW · 驱动装在泵上Armstrong · Design Envelope 4300Armstrong · Design Envelope 4300 450 hp indoors · drive on the pump450 hp indoors · 驱动装在泵上Wilo · Atmos TERA-SCH / TERA-SCH-HEWilo · Atmos TERA-SCH / TERA-SCH-HE 450 kW · pump without a built-in drive, motor450 kW · 泵上不带变频器的泵,电机Armstrong · 4600 split-caseArmstrong · 4600 中开泵 400 kW · pump without a built-in drive, motor400 kW · 泵上不带变频器的泵,电机Armstrong · IVS 102 controllerArmstrong · IVS 102 控制器 1,250 hp (900 kW) · separate drive1,250 hp (900 kW) · 独立变频器Grundfos · CUEGrundfos · CUE 560 kW · separate drive560 kW · 独立变频器Wilo · Wilo-EFCWilo · Wilo-EFC 132 kW · separate drive132 kW · 独立变频器
Grundfos NBE 55 kWArmstrong Tango 37 kWGrundfos TPE3 22 kWWilo GIGA2.0-I 22 kWGrundfos NBSE 15 hpWilo GIGA2.0-B 7.5 kWArmstrong 4300 450 hp indoorsWilo TERA-SCH 450 kWArmstrong 4600 400 kWArmstrong IVS 102 1,250 hpGrundfos CUE 560 kWWilo EFC 132 kW

drive on the pump驱动装在泵上 pump without a built-in drive, largest motor泵上不带变频器的泵,最大电机 separate drive, largest size独立变频器,最大规格

Largest size each source states, in kW; hp is drawn at 0.746 kW unless the source gives kW. Armstrong's 4300 family runs to 1,250 hp (900 kW), but its drive sits on the pump only up to 450 hp indoors; above that it has standalone control. Wilo TERA-SCH: largest article listed (Wilo states IE3 motors to 1,000 kW). The Grundfos sources read here do not state KPVS motor sizes, and Wilo Korea gives no power for its Wilo-Sensorless pump with an integrated inverter, so neither is drawn. Sizes are not efficiencies or duty points.各来源写明的最大规格,单位 kW;来源未给 kW 时按 0.746 kW/hp 换算。Armstrong 4300 系列到 1,250 hp(900 kW),但驱动装在泵上只到室内 450 hp,再往上为独立控制。Wilo TERA-SCH:所见最大型号(Wilo 写明 IE3 电机至 1,000 kW)。这里读到的 Grundfos 资料未写明 KPVS 电机规格,Wilo 韩国也未给出带集成变频器的 Wilo-Sensorless 泵的功率,所以两者都未画出。规格不是效率,也不是工况点。
In the sources read here, the largest stated built-in drives are 22 kW at Wilo and 55 kW at Grundfos; larger plant pumps get variable speed from a separate drive.在这里读到的资料中,写明的最大一体式驱动为 Wilo 22 kW、Grundfos 55 kW;更大的冷站水泵靠独立变频器调速。
22–55kW

Largest stated built-in drive at Wilo (Stratos GIGA2.0, 22 kW) and Grundfos (NBE, 55 kW) in the sources read here; Armstrong puts its drive on the 4300 up to 450 hp indoors这里读到的资料中写明的最大一体式驱动:Wilo(Stratos GIGA2.0,22 kW)和 Grundfos(NBE,55 kW);Armstrong 4300 室内到 450 hp 都把驱动装在泵上

Maker data厂商资料Tables表格
132kW

Largest Wilo-EFC drive in the Wilo sources read here, against Atmos TERA-SCH plant pumps, articles seen up to 450 kW; Wilo CC-HVAC panels cover 1.1–45 kW per pump, higher power on request. How Wilo drives its largest pumps is not stated there. Grundfos CUE reaches 560 kW这里读到的 Wilo 资料中 Wilo-EFC 的最大规格,而 Atmos TERA-SCH 冷站泵所见型号到 450 kW;Wilo CC-HVAC 控制柜每泵 1.1–45 kW,更大功率可询。这些资料未写明 Wilo 如何驱动其最大的泵。Grundfos CUE 到 560 kW

240

Wilo Atmos GIGA-B pumps (standard motor, no built-in drive) on DCX liquid-cooling CDUs; the only named CDU supply in the sources read here. DCX states that Wilo's pumps and VFDs are integrated across its FDUs (facility coolant distribution units)DCX 液冷 CDU 上的 Wilo Atmos GIGA-B 泵(标准电机,泵上不带变频器);这里读到的资料中唯一点名的 CDU 供货。DCX 称 Wilo 的泵和变频器已集成在其 FDU(设施侧冷却液分配单元)中

Maker statement, approximate厂商说法,约数Wilo KoreaWilo 韩国

The owner's judgement作者判断

Pumps move the heat from the racks to the plant and out. Armstrong, Grundfos and Wilo: which pumps run at variable speed, how large, and with which drives?水泵把热量从机柜送到冷站再送出去。Armstrong、Grundfos 和 Wilo:哪些泵能变频、做到多大、配什么变频器?

Willow Lei · judgementWillow Lei · 判断

All three makers offer variable speed in two forms: pumps with the drive built in, stated here up to 22 kW at Wilo, 55 kW at Grundfos and 450 hp at Armstrong (4300, indoors), and larger plant pumps that get variable speed from a separate drive, such as split-case pumps (Armstrong 4600 to 400 kW; Wilo TERA-SCH articles seen to 450 kW) and the 4300 above 450 hp.

The separate drives differ: Grundfos's CUE reaches 560 kW with BACnet built in and Armstrong's IVS 102 1,250 hp, while the Wilo sources read here state the Wilo-EFC to 132 kW without mentioning BACnet, and CC-HVAC panels to 45 kW per pump (higher on request) with an optional BACnet module; on the CDU side, in the sources read here, only Wilo names a supply, about 240 Atmos GIGA-B pumps (standard motor, no built-in drive) on DCX units, and DCX states that Wilo's pumps and VFDs are integrated across its FDUs (facility coolant distribution units).

In my judgement, for AI sites the question is no longer whether a pump is variable-speed, but how pumps, drives, the CDU and the plant are controlled together when GPU load swings; none of the sources read here gives data on that.

三家都提供两种变频方式:驱动装在泵上的一体式变频泵,这里写明的最大规格为 Wilo 22 kW、Grundfos 55 kW、Armstrong 4300 室内 450 hp;更大的冷站水泵则靠独立变频器调速,例如中开泵(Armstrong 4600 到 400 kW;Wilo TERA-SCH 所见型号到 450 kW)以及 450 hp 以上的 4300。

独立变频器各不相同:Grundfos CUE 到 560 kW、内置 BACnet,Armstrong IVS 102 到 1,250 hp;这里读到的 Wilo 资料写明 Wilo-EFC 到 132 kW、未提 BACnet,CC-HVAC 控制柜每泵到 45 kW(更大功率可询)、可选配 BACnet 模块;这里读到的资料中,CDU 侧只有 Wilo 点名供货:DCX 设备上约 240 台 Atmos GIGA-B(标准电机,泵上不带变频器),DCX 称 Wilo 的泵和变频器已集成在其 FDU(设施侧冷却液分配单元)中。

我的判断是:对 AI 机房,问题不再是泵是否变频,而是 GPU 负载波动时,泵、变频器、CDU 和冷站如何协同控制;这里读到的资料都没有给出这方面的数据。

Sources: 来源:[1] [2] [3] [4] [5] [6] [7] [8] [9]

Timeline slice: the latest six events that happened, then the stated plans时间轴切片:最近六个已发生事件,然后是公布的计划

Filled dot: happened. Hollow dot and "Planned": a stated plan with its window; it stays a plan until a source confirms it happened. The full six-year roadmap is further down.实心点:已发生。空心点加"计划":公司公布的计划及其时间窗口;在有来源确认发生前一直是计划。完整六年路线图在下方。
Full roadmap 2023 Q4 – 2029 Q3 (3 events), who earns the revenue, and the method完整路线图 2023 年第四季度至 2029 年第三季度(3 个事件)、谁获得收入、方法

Roadmap, 2023 Q4 – 2029 Q3路线图,2023 年第四季度至 2029 年第三季度

Dated events from official sources. Planned events show the window the source states; passing the window does not prove shipment. No future model is inferred.来自官方来源的有日期事件。计划事件显示来源给出的时间窗口;窗口过去并不代表已经出货。不推测未来型号。

Who earns the revenue谁获得这部分收入

Listed companies in the registry behind the products on this page: 本页产品背后、在上市公司名单中的公司:. Outside the registry: 不在名单中:Armstrong Fluid Technology (private非上市); Grundfos (private非上市); Wilo (private非上市). See the value-chain map查看产业链地图

Method方法

Owner scope 2026-10-17: Armstrong, Grundfos and Wilo only, variable-speed pumps first, then fixed-speed plant pumps with each maker's own drive. Values come from each maker's product pages, data booklets, submittals and press releases; each source was extracted by two different models and ruled against the saved text. Where two of a maker's documents disagree, the newer one is used and the other is noted. Evidence cut-off 2026-10-17. Personal research, not investment advice.作者 2026-10-17 定的范围:只看 Armstrong、Grundfos 和 Wilo,先看变频泵,再看定速冷站泵及各厂商自己的变频器。数值来自各厂商的产品页、样本、提交资料和新闻稿;每个来源由两个不同模型分别提取,并对照保存的原文裁定。同一厂商两份资料不一致时,采用较新的一份并注明另一份。证据截止 2026-10-17。个人研究,不构成投资建议。

Database view: built-in-drive pumps, plant pumps and drives数据库视图:一体式变频泵、冷站大泵与变频器13 rows13 行
Showing显示 13

○ = not stated by the vendor (explained once here, not repeated in words in each cell).○ = 厂商未标称(只在此说明一次,不在每格重复文字)。

Pumps with a built-in drive驱动装在泵上的一体式变频泵

Family envelopes as each maker states them; maximum flow and maximum head are not reached together. Grundfos and Wilo values are 50 Hz unless marked; Armstrong values are from its North American pages, which do not state the frequency. Wilo Korea also lists a Wilo-Sensorless in-line pump with an integrated inverter (up to 1,700 m³/h and 75 m) without stating its power.按各厂商写明的系列范围;最大流量和最大扬程不会同时达到。Grundfos 和 Wilo 除标注外为 50 Hz;Armstrong 数值来自其北美页面,页面未写明频率。Wilo 韩国还列出带集成变频器的 Wilo-Sensorless 管道泵(最高 1,700 m³/h、75 m),但未写明功率。

Company and line公司与系列Type型式Motor and drive电机与驱动Motor power电机功率Maximum flow and head最大流量与扬程Fluid temperature and pressure介质温度与压力Where the maker ties it to data centres厂商与数据中心的关联
Armstrong · Design Envelope 4300Armstrong · Design Envelope 4300Vertical in-line, single pump立式管道泵,单泵Integrated variable-speed controls, sensorless; permanent-magnet motors to 100 hp (IE5 stated in the 1–10 hp specification), induction motors above集成变频控制,无传感器控制;永磁电机至 100 hp(1–10 hp 规格书写明 IE5),更大功率为感应电机0.25–900 kW family; drive on the pump up to 450 hp indoors (125 hp outdoors), 450–1,250 hp with standalone control系列 0.25–900 kW;室内 450 hp 以下驱动装在泵上(室外 125 hp),450–1,250 hp 为独立控制Up to 25,000 USgpm (1,500 L/s); 10–300 ft (3–90 m)最高 25,000 USgpm(1,500 L/s);10–300 ft(3–90 m)Up to 150 °C; pressure by flange class (for example 175 psig at 140 °F)最高 150 °C;压力按法兰等级(例如 140 °F 时 175 psig)2014 Armstrong data-centre guide uses it on the primary, secondary and condenser loops of a chilled-water plantArmstrong 2014 年数据中心指南把它用于冷冻水冷站的一次、二次和冷却水回路
Armstrong · Design Envelope Tango (4322 / 4372 / 4332)Armstrong · Design Envelope Tango(4322 / 4372 / 4332)Two pumps in one casing; parallel sensorless control standard一个泵壳内两台泵;标配并联无传感器控制Integrated variable-speed controls per pump; permanent-magnet motors, IE5 stated for the 4332每台泵集成变频控制;永磁电机,4332 写明 IE54322 / 4372 to 7.5 kW; 4332 11–37 kW (2024 announcement: 11–30 kW)4322 / 4372 至 7.5 kW;4332 为 11–37 kW(2024 年发布时为 11–30 kW)4332 up to 2,000 USgpm both pumps together and 200 ft (60 m) (2024 announcement: 160 ft)4332 两台泵合计最高 2,000 USgpm,扬程 200 ft(60 m)(2024 年发布时为 160 ft)Up to 121 °C (4332); pressure not stated最高 121 °C(4332);压力未写明Armstrong solution outline (June 2026) lists data centers under mission-critical duty, each pump sized for 100 % flowArmstrong 方案手册(2026 年 6 月)把数据中心列为关键任务工况,每台泵按 100% 流量选型
Grundfos · TPE3 / TPE3 DGrundfos · TPE3 / TPE3 DIn-line, single or twin head管道泵,单头或双头Frequency converter built into the permanent-magnet motor, IE5; built-in differential-pressure and temperature sensor变频器内置于永磁电机,IE5;内置压差和温度传感器0.25–22 kW (50 Hz booklet)0.25–22 kW(50 Hz 样本)50 Hz: up to 565 m³/h and 78 m; US 60 Hz sheet: up to 500 gpm and 80 ft50 Hz:最高 565 m³/h、78 m;美国 60 Hz:最高 500 gpm、80 ft−25 to 120 °C; 16 bar (PN 25 version: 25 bar)−25 至 120 °C;16 bar(PN 25 版本:25 bar)Listed in Grundfos Data Center Cooling Solutions (06.2023); twin head as built-in redundancy列入 Grundfos 数据中心冷却方案(2023 年 6 月);双头泵作为内置冗余
Grundfos · NBSEGrundfos · NBSEEnd-suction, split-coupled端吸泵,分体联轴器Permanent-magnet MLE motor with variable-frequency drive and controls; stated to exceed IE5MLE 永磁电机,集成变频器和控制;写明效率超过 IE53–15 hp (about 2.2–11 kW)3–15 hp(约 2.2–11 kW)Up to 1,200 gpm and 270 ft (US 60 Hz leaflet, 2021)最高 1,200 gpm、270 ft(美国 60 Hz 单页,2021 年)−13 to 248 °F (−25 to 120 °C); 232 psi−13 至 248 °F(−25 至 120 °C);232 psiListed in Grundfos Data Center Cooling Solutions (06.2023); leaflet applications include chilled and condenser water列入 Grundfos 数据中心冷却方案(2023 年 6 月);单页列出的用途包括冷冻水和冷却水
Grundfos · NBE / NKE (larger integrated sizes)Grundfos · NBE / NKE(较大的一体式规格)End-suction, close-coupled (NBE) or long-coupled (NKE)端吸泵,直联(NBE)或长联(NKE)Frequency converter in the MGE motor; IE5 to 22 kW, IE4 and IE5 at 30–55 kW变频器集成于 MGE 电机;22 kW 以下 IE5,30–55 kW 为 IE4 和 IE50.25–55 kW0.25–55 kWBy version: up to 210, 400 or 1,100 m³/h; up to 85 or 95 m (50 Hz)按版本:最高 210、400 或 1,100 m³/h;最高 85 或 95 m(50 Hz)−25 to 140 °C, 16 bar (sensor version); −45 to 220 °C, 25 bar (no-sensor version)−25 至 140 °C、16 bar(带传感器版);−45 至 220 °C、25 bar(无传感器版)Not in the Grundfos data-centre brochure (06.2023)未列入 Grundfos 数据中心手册(2023 年 6 月)
Wilo · Stratos GIGA2.0-I / -DWilo · Stratos GIGA2.0-I / -DIn-line, single (I) or twin (D)管道泵,单泵(I)或双泵(D)EC motor with integrated speed control, IE5; with or without a built-in differential-pressure sensorEC 电机集成调速,IE5;可带或不带内置压差传感器0.37–22 kW0.37–22 kWNo family figure on the UK page; US 60 Hz: up to 702 gpm and 153 ft英国页面未给系列数值;美国 60 Hz:最高 702 gpm、153 ft−20 to 140 °C; 16 bar to 120 °C, 13 bar to 140 °C−20 至 140 °C;120 °C 以下 16 bar,140 °C 以下 13 barWilo USA lists it among its data-center pump solutionsWilo 美国把它列入数据中心水泵方案
Wilo · Stratos GIGA2.0-BWilo · Stratos GIGA2.0-BClose-coupled (monobloc)直联单体泵EC motor with integrated speed control, IE5EC 电机集成调速,IE50.75–7.5 kW (UK series page)0.75–7.5 kW(英国系列页)not stated未披露not stated未披露Wilo Korea's data-centre page lists a Stratos GIGA-B (0.75–22 kW, up to 520 m³/h and 82 m as stated there; generation not stated)Wilo 韩国数据中心页面列出 Stratos GIGA-B(按该页:0.75–22 kW,最高 520 m³/h、82 m;未写明代次)

Large plant pumps: fixed speed, with a separate drive for variable speed冷站大泵:定速泵,变频需另配变频器

Split-case pumps for the large chilled- and condenser-water duties; maximum flow and maximum head are not reached together. The pump has no drive; variable speed comes from a separate drive, such as those in the next table.用于大流量冷冻水和冷却水的中开泵;最大流量和最大扬程不会同时达到。泵本身不带驱动;变频靠另配的变频器,例如下表所列。

Company and line公司与系列Type型式Motor电机Motor power电机功率Maximum flow and head最大流量与扬程Fluid temperature and pressure介质温度与压力Where the maker ties it to data centres厂商与数据中心的关联
Armstrong · 4600 split-caseArmstrong · 4600 中开泵Horizontal split-case, base-mounted卧式中开泵,底座安装NEMA Premium motors, all suitable for inverter-fed service; no drive on the pumpNEMA Premium 电机,均适合变频供电;泵上不带驱动1.1–400 kW (1.5–500 hp)1.1–400 kW(1.5–500 hp)Up to 7,000 USgpm (440 L/s) and 600 ft (180 m), North American page; UK page up to 365 L/s and 200 m最高 7,000 USgpm(440 L/s)、600 ft(180 m),北美页面;英国页面最高 365 L/s、200 mUp to 107 °C; pressure by flange class (for example 175 psig at 150 °F)最高 107 °C;压力按法兰等级(例如 150 °F 时 175 psig)Not named in the Armstrong data-centre material read here, which names Design Envelope pumps这里读到的 Armstrong 数据中心资料未点名,资料点名的是 Design Envelope 泵
Grundfos · KPVSGrundfos · KPVSVertical split-case立式中开泵not stated未披露not stated未披露Up to 13,000 gpm (2,953 m³/h) and 420 ft (128 m), 60 Hz最高 13,000 gpm(2,953 m³/h)、420 ft(128 m),60 Hz−20 to 275 °F; 300 psi−20 至 275 °F;300 psiListed in Grundfos Data Center Cooling Solutions; 2025 US hyperscale case: Grundfos states KPVS was 5 % (chilled water) and 4 % (condenser water) more efficient than competitors' specified pumps列入 Grundfos 数据中心冷却方案;2025 年美国超大规模案例:Grundfos 称 KPVS 效率比竞争对手指定的泵高 5%(冷冻水)和 4%(冷却水)
Wilo · Atmos TERA-SCH / TERA-SCH-HEWilo · Atmos TERA-SCH / TERA-SCH-HEAxially split case, base-mounted轴向中开泵,底座安装2-, 4- and 6-pole motors; Wilo states "IE3-standard to 1000 kW (IE4 on request)"2、4、6 极电机;Wilo 写明“IE3 标准至 1000 kW(IE4 可选)”Largest article listed 450 kW (40 of 116 articles shown)所见最大型号 450 kW(列表显示 116 个型号中的 40 个)Standard up to 4,500 m³/h; head not stated标准最高 4,500 m³/h;扬程未写明−20 to 120 °C; PN 10 or PN 16−20 至 120 °C;PN 10 或 PN 16TERA-SCH-HE listed on the Wilo USA data-center pageTERA-SCH-HE 列于 Wilo 美国数据中心页面

The makers' own drives厂商自己的变频器

Each maker's variable-frequency drive or controller for pumps. Efficiency class, control functions and protocols as stated; none of these sources names the drive for a data centre.各厂商用于水泵的变频器或控制器。效率等级、控制功能和通信协议按来源写明;这些来源都没有点名把变频器用于数据中心。

Company and drive公司与变频器Power range功率范围Drive efficiency class变频器效率等级Pump control functions水泵控制功能Communications通信Harmonics谐波Role用途
Armstrong · IVS 102 controllerArmstrong · IVS 102 控制器1–1,250 hp (0.75–900 kW)1–1,250 hp(0.75–900 kW)not stated未披露Sensorless control, constant flow and pressure; parallel sensorless optional; can stage up to two constant-speed pumps无传感器控制、恒流量和恒压力;并联无传感器控制可选;可启停最多两台定速泵BACnet MS/TP, BACnet/IP and Modbus RTU standard (4300 450 hp submittal); IVS 102 submittal: Modbus RTU, Johnson N2, Siemens FLN, BACnet标配 BACnet MS/TP、BACnet/IP 和 Modbus RTU(4300 450 hp 提交资料);IVS 102 提交资料:Modbus RTU、Johnson N2、Siemens FLN、BACnetDual DC-link reactors, equal to a 5 % AC line reactor; no system-wide guarantee双直流母线电抗器,相当于 5% 交流进线电抗器;不保证系统谐波Armstrong's variable-speed controller on many Design Envelope pumps; the 4300 from 450 to 1,250 hp is supplied with standalone controlArmstrong 用于许多 Design Envelope 泵的变频控制器;4300 在 450–1,250 hp 配独立控制
Grundfos · CUEGrundfos · CUE0.55–560 kW at 3 × 380–500 V (to 315 kW at 525–690 V)3 × 380–500 V 时 0.55–560 kW(525–690 V 时至 315 kW)IE2 (EN 50598-2)IE2(EN 50598-2)Constant and proportional differential pressure including sensorless modes, flow estimation, duty/standby, multi-pump cascade恒压差和比例压差(含无传感器模式)、流量估算、主备切换、多泵级联Modbus RTU, BACnet MS/TP and GENIbus built in; BACnet IP optional内置 Modbus RTU、BACnet MS/TP 和 GENIbus;BACnet IP 可选Harmonic filter (AHF) optional谐波滤波器(AHF)可选External drive for Grundfos pumps (data booklet 05.2026)用于 Grundfos 水泵的外置变频器(2026 年 5 月样本)
Wilo · Wilo-EFCWilo · Wilo-EFC0.37–132 kW, 3 × 380–480 V0.37–132 kW,3 × 380–480 Vnot stated未披露Cascade control, four PID controllers, dry-run and low-flow protection; sensorless control not stated级联控制、4 个 PID 控制器、干运行和低流量保护;未写明无传感器控制Wilo FC and Modbus RTU built in; other fieldbuses by option; BACnet not stated内置 Wilo FC 和 Modbus RTU;其他总线可选;未写明 BACnetDC-link reactors; no THD figure直流母线电抗器;未给总谐波畸变率External drive for fixed-speed pumps with asynchronous or PM motors; Wilo CC-HVAC panels (1.1–45 kW per pump, higher power on request) are the HVAC control option, with an optional BACnet module外置变频器,用于异步或永磁电机的定速泵;Wilo CC-HVAC 控制柜(每泵 1.1–45 kW,更大功率可询)是暖通控制选项,可选配 BACnet 模块